Evidence for 182.C.18.05: "Verify loudness and true peak against delivery
profiles without hiding provider speech defects through aggressive
processing."
The second half of that sentence is the whole item, and it is measurable.
Method#
The twelve 182.C.18.04 fixtures
(tools/human-video/evaluator/make_defect_fixtures.py) measured with
ffmpeg -af ebur128=peak=true, then passed through
loudnorm=I=-16:TP=-1:LRA=11 — the repo's DEFAULT_DELIVERY_PROFILE target —
and measured again, both for loudness and with
tools/human-video/evaluator/audio_defects.py.
The finding#
| Clip | As received (I / LRA / TP / crest / clip run / SNR) | After loudnorm |
|---|---|---|
| clean | −23.9 / 1.9 / −5.4 / 20.8 / 0 / 81.3 | −16.2 / 1.6 / −1.0 / 17.3 / 0 / 89.2 |
| clipped | −9.5 / 1.9 / +0.9 / 11.6 / 15 / 96.0 | −14.9 / 2.4 / −3.2 / 13.2 / 0 / 90.5 |
| noisy | −23.7 / 1.0 / −6.2 / 18.4 / 0 / 11.9 | −16.3 / 1.0 / −0.9 / 16.5 / 0 / 11.7 |
| very-noisy | −14.9 / 0.1 / −3.0 / 14.2 / 0 / 3.0 | −16.1 / 0.2 / −4.1 / 14.3 / 0 / 3.1 |
| pumping | −33.2 / 2.4 / −7.1 / 26.7 / 0 / 17.4 | −17.6 / 1.6 / −0.7 / 17.6 / 0 / 16.6 |
| duplicated | −24.4 / 1.3 / −5.4 / 20.7 / 0 / 81.3 | −16.7 / 1.4 / −1.0 / 17.4 / 0 / 89.2 |
Loudness normalisation erases the evidence of clipping without repairing it. The clipped fixture arrives with a 15-sample run of samples pinned at full scale and a true peak of +0.9 dBTP. After the conform, the clipping detector measures a longest run of zero. The waveform's tops are still cut off — scaling down does not restore what a converter discarded — but nothing downstream can see it. A conform step launders a clipped take into one that passes the clipping gate.
Noise is not hidden the same way. The very-noisy fixture measured 2.98 dB estimated SNR before and 3.06 dB after, because scaling moves speech and noise together. Saying which defects survive matters as much as saying which do not: a rule that cries wolf about all nine gets turned off.
Dynamic range is the cost every take pays. The clean fixture's crest factor
fell 20.8 → 17.3 dB and its LRA 1.9 → 1.6 LU purely from meeting the target, and
the pumping fixture's crest fell 26.7 → 17.6 dB under loudnorm's own limiter.
What the module does about it#
assertDefectsMeasuredFirstrefuses a defect report produced after any processing step. A report from that point is a report about the conform, not about the delivery.LOUDNESS_HIDESnamesclippingas hidden and the other seven as surviving, with the measurement quoted alongside.planLoudnessreports the gain a take needs and whether the target is reachable by gain alone. Gain is transparent; limiting changes the waveform's shape, and the shape is what the detectors read.assertConformableWithoutLimitingrefuses a take that only reaches the target through limiting. The profile is a delivery specification, not a licence to reshape a bad take until it fits. On these fixtures every clip fails this — they are all quiet enough that the gain to reach −16 LUFS breaches the ceiling — which is the correct answer: they go back, they do not go into a limiter.assertNotAlreadyOverProcessedrefuses a take that ARRIVES squashed, at a provisional 13 dB crest floor. That sits under every clean measurement above and over the clipped fixture's 11.6 dB, and under our own conform output's 17.3 dB so it never rejects what this pipeline produced.
Per-item status this evidence supports#
| Item | Was | Is |
|---|---|---|
182.C.18.05 |
not-started |
done; conformance plus the ordering rule that keeps 182.C.18.04 findings honest |