date: 2026-05-15 owner: SRE Lead decision: PASS
Drill scope covered admin queue triage, agentic kill-switch arming, fallback route activation, status-banner publication, and recovery to normal service.
| Drill | Evidence | Result |
|---|---|---|
| Admin kill-switch requires a reason | apps/oshun/admin/e2e/agentic-operations-flows.spec.ts |
pass |
| Incident fallback path opens and records mitigation | apps/oshun/admin/e2e/incident-orchestration-flows.spec.ts |
pass |
| Shell fallback route documented | docs/runbooks/shell-outage.md |
pass |
| Provider fallback route documented | docs/runbooks/provider-failover.md |
pass |
RTO observed: 11 minutes. RPO observed: 0 minutes.