Evidence for 182.C.19.05, which names seven artifacts: malformed
teeth/tongue/lips, jaw discontinuity, asymmetry spikes, face boundary tearing,
extra limbs/digits, fused props, and impossible object contact.
One of the seven is now detected. Four candidate approaches were measured and all four failed, and the failures are the more useful half of this page — somebody will otherwise build them again.
Fixture#
The committed three-panel probe
../2026-09-10-face-mesh-artifact-probe/clean-vs-doubled-mouth-vs-tear.png: the
same real face, clean, with a doubled mouth, and with a horizontal band
displaced (boundary tearing). A fourth panel, a vertical tear, is built from
the clean one the same way, to validate the column axis against a fault known to
be there.
What works: line continuity#
A tear is a displacement — a band shifted, so at its edges one row no longer continues into the next. Correlation between adjacent rows measures exactly that.
| Panel | worst row corr | rows < 0.7 | worst col corr | cols < 0.7 |
|---|---|---|---|---|
| clean | 0.796 | 0 | 0.810 | 0 |
| doubled mouth | 0.796 | 0 | 0.810 | 0 |
| torn (horizontal) | 0.292 | 2 | 0.833 | 0 |
| torn (vertical) | 0.558 | 1 | 0.224 | 2 |
It also names where: row 168 for the horizontal tear and column 170 for the vertical one, both the displaced band's edge. And the axis with the lower minimum names the tear's orientation — a vertical tear disturbs some rows too (0.558), but far less than it disturbs columns.
A 0.7 threshold sits between 0.796 and 0.292 with room on both sides. Two discontinuous lines are required rather than one, because a displaced band has two edges and a single bad line is as likely to be a hard cut inside the frame — a title card edge, a split screen.
What does not work#
Segmentation consistency — the item's own suggested candidate#
| Panel | face-skin components | largest share | holes | boundary roughness |
|---|---|---|---|---|
| clean | 2 (1 over 100 px) | 1.000 | 0 | 19.28 |
| doubled mouth | 1 | 1.000 | 0 | 20.26 |
| torn | 1 | 1.000 | 0 | 25.63 |
Every structural measure is identical. Roughness moves 33% for the tear and only 5% for the doubled mouth — inside the difference between two ordinary frames.
Copy-move block matching#
The idea that a doubled mouth is a pasted copy. 24×24 blocks, stride 8, flat blocks skipped, pairs at least 40 px apart:
| Panel | best distant correlation | best pair | pairs > 0.99 |
|---|---|---|---|
| clean | 0.9709 | (140,156) ↔ (188,260) | 0 |
| doubled mouth | 0.9709 | (140,156) ↔ (188,260) | 0 |
| torn | 0.9707 | (140,156) ↔ (188,260) | 0 |
Identical on all three, on the same coordinate pair. The doubled mouth is not a pixel copy, so block matching cannot see it.
Dense face-mesh asymmetry and lip curvature#
Disqualified earlier the same day in ../2026-09-10-face-mesh-artifact-probe/:
the mesh scored the doubled mouth as more regular than the clean face.
Still undetected#
| Artifact | Status |
|---|---|
| malformed teeth/tongue/lips | four approaches measured and failed; remaining candidate is a trained detector (182.C.33) |
| jaw discontinuity | no fixture; a hard displacement would show here, a soft malformation would not |
| asymmetry spikes | mesh asymmetry disqualified |
| extra limbs/digits | hand keypoint models emit 21 keypoints unconditionally |
| fused props, impossible object contact | needs scene understanding, which nothing staged here provides |
Reproducing#
python tools/human-video/evaluator/frame_continuity.py --image <frame.png>
Per-item status this evidence supports#
| Item | Was | Is |
|---|---|---|
182.C.19.05 |
not-started |
blocked-corpus: 1 of 7 detected, 4 approaches disqualified, malformed mouth needs 182.C.33 |